Edition GB –B09
REMKO
WIRELESS REMOTE CONTROL
FOR MULTITALENT HEAT PUMP MANAGER
Operation - Technology - Spare parts
Vue de la page 0
1 2 3 4 5 6 ... 31 32

Résumé du contenu

Page 1 - WIRELESS REMOTE CONTROL

Edition GB –B09REMKO WIRELESS REMOTE CONTROL FOR MULTITALENT HEAT PUMP MANAGEROperation - Technology - Spare parts

Page 2

Heating circuit 1/2Parameter Function CommentsActual/Target room temp.Current room temperature according to heating programme and operating modeRoom t

Page 3 - Contents

User menuSystemThis menu contains all the settings which can be adjusted by the user of the system.Parameter Value range Default OV*) CommentsLanguage

Page 4

Heating circuit 2Parameter Value range Default OV CommentsTarget room temp. 1 *) 5°C - 40°C 20°CAdjust the desired room temperatureTarget room temp. 1

Page 5 - Operation

ParameterValue rangeDefault OV CommentsHeating curve 0.00 - 3.00 1.20The curve's slope indicates by how many degrees the supply temperature will

Page 6

Parameter Value range Default OV CommentsRoom influence 00 - 20 10The room sensor influence is only active when the analogue room device FBR (room senso

Page 7 - Target room temp. 1

Heating period 1 Heating period 2 Heating period 3MonTuesWedThursFriSatSunTime programmes menuAdjusting a time programmeAll time programmes can be set

Page 8

Heating period 1 Heating period 2 Heating period 3MonTuesWedThursFriSatSunHeating programme 2 => Factory setting: Mon to Fri: 6:00am to 8:00am, 4:

Page 9

Parameter Function CommentsTime (hh:mm) Set hour, F-key [==>], hh:mm, set minutes(Not with a time master or DCF in the system)The clock may lose up

Page 10 - Solar / MF

Service menuValues (parameters) are summarised here in order to enable quick access for customer service.Parameter CommentsSoftware number XXX.XXSoftw

Page 11 - Hot water

Parameter Value range Default OV CommentsChange code 0000 - 9999 0000This is where you can change the default code number [0000] => protection agai

Page 13 - Heating circuit 2 (continued)

Parameter Value range Default OV CommentsMin limit *)00 = On 01 = Off 02 = Permanent00HA minimum limit(not in cascade operation)Reduces condensate for

Page 14

Parameter Value range Default OV CommentsCharge pump lock Off/On OnThe charge pump is only switched on once the HA temperature has exceeded the tank t

Page 15

Parameter Value range Default OV CommentsHC functionDefault, Const. supply temp.DefaultHeating circuit function selectionDefault => default heating

Page 16

Parameter Value range Default OV CommentsMax supply temp. 20°C - 110°C 55°CThe calculated target supply temperature for the heating circuit is limited

Page 17 - Time/Date menu

General mode of operationHeating circuit regulationWeather-based regulation The set heating curve is used to determine the boiler or supply temperatur

Page 18 - ! CAUTION

Troubleshooting and customer serviceThe units and components are manufactured using state-of-the-art production methods and tested several times to v

Page 19

Only the error with the highest priority is displayed.- The message "Error" appears on the standard display and the error number in the Fav

Page 20 - System (continued)

1. Read this manual carefully before commissioning.2. Fit the controller (see chapter “Installation”).3. Wait until the message Installation appear

Page 21 - Hot water *)

Changing the batteryIf the battery symbol shown below displays 0%, the battery should be changed within the next week.100% 50% 0%System busHeating sys

Page 22

Technical dataRadio frequency MHz 868,0 - 868,6Max. transmission power mW 4Supply voltage 2x LR6 alkaline cellPower consumption mA 0,15Protection cate

Page 23 - Heating circuit (continued)

ContentsRead these operating instructions carefully before commissioning/using the unit!These instructions are an integral part of the unit and must a

Page 24

Notes

Page 25

Notes

Page 26

We reserve the right to make technical changes and provide no warranty as to the accuracy of this data!ConsultationThanks to intensive training, our c

Page 27 - Commissioning

Safety notesWarranty The precondition for all warranty claims is that the orderer or his customer has fully filled out the "warranty registration

Page 28 - System bus

Controls during normal operation The wireless remote control is controlled with the following keys.The rotary knob (A) can be used to toggle between t

Page 29 - Technical data

(Heating OFF and Water heating OFF, Frost protection function only)Setting the operating modeDuring normal operation, press the F-key next to “OK”.Aut

Page 30

Controls in operating modeCBAIf a parameter, a function/display or a parameter menu is not supported by the connected heating circuit controller, it i

Page 31

Overview of the operating menusMenus Description Sub-menus DescriptionDisplayDisplays system values (e.g. sensor and target values). Adjustment is not

Page 32 - REMKO INTERNATIONAL

Display menuThe parameters are selected using the rotary knob. (HA = heating appliance)SystemParameter Function CommentsOutdoor temp. Displays the ou